Page 1
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
M
a
n
tis
P
o
w
e
r
H
u
m
i
d
i
f
i
e
r
B
u
r
n
e
r
s
E
x
h
a
u
s
t
F
a
n
B
l
o
w
e
r
H
i
M
e
d
L
o
w
F
r
o
n
t
R
e
a
r
POWER-VENT
HIGH-EFFICIENCY
FIREPLACE WITH
BAY WINDOW
MODELS
PV-28SV50-(BN,BP)-1
PV-28SV55-(CN,CP,GN,GP)-1
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer’s in-
structions, this product could expose you to sub-
stances in fuel or from fuel combustion which can
cause death or serious illness.
Installer: Leave this manual with the
appliance.
Consumer: Retain this manual for future
reference.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: If the information in these in-
structions are not followed exactly, a fire or ex-
plosion may result causing property damage,
personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
state or local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
EMPIRE
EMPIRE
Comfort Systems
This appliance is NOT to be installed in Canada.
Seitenansicht 0
1 2 3 4 5 6 ... 55 56

Inhaltsverzeichnis

Seite 1 - OWNER’S MANUAL

Page 1INSTALLATION INSTRUCTIONSANDOWNER’S MANUALMantisPowerHumidifierBurnersExhaustFanBlowerHiMedLowFrontRearPOWER-VENT HIGH-EFFICIENCY FIREPLACE WITH

Seite 2 - TABLE OF CONTENTS

22618-17-0308Page 101. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide

Seite 3 - IMPORTANT SAFETY INFORMATION

22618-17-0308 Page 11SPECIFICATIONSHeater with Pedestal and Single Flue Adaptor1 Flue Outlet 1 1/2” PVC Pipe2 Air Inlet3 Electric Cord4 3/8” Flare Con

Seite 4 - SOME POINTS TO REMEMBER

22618-17-0308Page 12SPECIFICATIONS - (continued)Figure 4Heater without pedestal1 Flue Outlet 1 1/2” PVC Pipe2 Air Inlet3 Electric Cord4 3/8” Flare Con

Seite 5 - 22618-17-0308 Page 5

22618-17-0308 Page 13SPECIFICATIONS - (continued)Figure 5Fireplace Insert with Mantel Surround with Slim Top Panel1 Flue Outlet 1 1/2” PVC Pipe2 Air I

Seite 6 - FLARE SHUT OFF VALVE

22618-17-0308Page 14SPECIFICATIONS - (continued)Figure 6Fireplace Insert with Mantel Surround with Short Top Panel1 Flue Outlet 1 1/2” PVC Pipe2 Air I

Seite 7 - INTRODUCTION

22618-17-0308 Page 15CLEARANCE TO COMBUSTIBLESFreestanding ModelsFreestanding UnitsA Rear Wall to Heater 0” (2” Single Flue and 1 1/4” Direct Vent for

Seite 8

22618-17-0308Page 16ROUGH FRAMING DIMENSIONSINSERT INTO MASONRY FIREPLACEA - 13 /34” MIN. CO-LINEAR 8 1/2” WHEN USING DIRECT VENTING PVVK-2

Seite 9 - CLEARANCES FOR DIRECT VENT

22618-17-0308 Page 17WALL CLEARANCESFigure 14

Seite 10 - CLEARANCES FOR SINGLE FLUE

22618-17-0308Page 18All LogsThe positioning of the logs is critical to the safe and clean opera-tion of this heater. Sooting and other problems may re

Seite 11 - SPECIFICATIONS

22618-17-0308 Page 19VENT EXAMPLES FOR SINGLE FLUEMax Vent Run - 40 ft. Equivalent With Three (3) 90° ElbowsSpecial Note: The vent terminal 90° elbow

Seite 12 - SPECIFICATIONS - (continued)

22618-17-0308Page 2TABLE OF CONTENTSImportant Safety Information ...

Seite 13

22618-17-0308Page 20VENT EXAMPLES FOR SINGLE FLUE (cont.)Figure 19Single Flue - Vertical Vent RunH = 36’V = 1’(1) - 90° = 3’Total = 40’SINGLE F

Seite 14

22618-17-0308 Page 21Figure 23Single Flue - Vertical Vent Run with 45 degree elbowsVENT EXAMPLES FOR SINGLE FLUE (cont.)Figure 22Minimum Exterior Gra

Seite 15 - CLEARANCE TO COMBUSTIBLES

22618-17-0308Page 22Available from Empire Comfort Systems, Inc.PVVK-CFA FLEX VENT KITThe flex vent kit is a flexible vent hose that is 42” in length. Th

Seite 16 - INSERT INTO MASONRY FIREPLACE

22618-17-0308 Page 23Available from Empire Comfort Systems, Inc.INSTALL FOAM GASKETFLUE ADAPTORPLASTIC GASKETTHREADED CONNECTORAttach flue adaptor to b

Seite 17 - WALL CLEARANCES

22618-17-0308Page 24HORIZONTAL EXAMPLES FOR COLINEAR DIRECT VENTFigure 27Enhanced top view of Figure 26Figure 26Max Vent Run - 40 ft. Equivalent With

Seite 18 - LOG SET DIAGRAM - A

22618-17-0308 Page 25VERTICAL EXAMPLES FOR COLINEAR DIRECT VENTFigure 28Calculation example of vent run maximum 40’Determining Minimum Vent Height Abo

Seite 19 - VENT EXAMPLES FOR SINGLE FLUE

22618-17-0308Page 26VERTICAL EXAMPLES FOR COLINEAR DIRECT VENTSINGLE FLUEMODEL PVVK-SHCO-LINEARDIRECT VENT ADAPTERMODEL PVCA12XHEIGHTFLASHINGREQUIREDH

Seite 20 - MODEL #PVVK-SH

22618-17-0308 Page 27PVCA HORIZONTAL COLINEAR DIRECT VENT ADAPTORCOLINEAR ADAPTER1. Attach colinear adaptor to back of heater with two (2) s

Seite 21 - (SUPPLIED BY INSTALLER)

22618-17-0308Page 28PVVTC TERMINATION CAP VENT KITAvailable from Empire Comfort Systems, Inc.Termination CapVertical exhaust cap used with 1 1/2” PVC

Seite 22 - PVVK-CFA FLEX VENT KIT

22618-17-0308 Page 29PVCT COLINEAR TRANSITION VENT KITAvailable from Empire Comfort Systems, Inc.Flat Roof or Chimney Application1. Attach plate to c

Seite 23 - 22618-17-0308 Page 23

22618-17-0308 Page 3IMPORTANT SAFETY INFORMATIONTHIS IS A HEATING APPLIANCEDO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.• Due to hig

Seite 24 - 22618-17-0308Page 24

22618-17-0308Page 30DIRECT VENT INSTALLATION INSTRUCTIONSFLUE CENTEREXTERIOR GRADEMANTELGAS SUPPLY12” (30.5cm)MIN.SURROUNDDO NOT GLUETHIS POINTDIRECT

Seite 25 - 22618-17-0308 Page 25

22618-17-0308 Page 31DIRECT VENT INSTALLATION INSTRUCTIONS (cont.)EXTERIOR GRADEFLUE CENTER1 1/4”(3.2cm)MIN.12”(30.5cm)MIN.FLOOR PROTECTIONFLOOR PROTE

Seite 26 - 3” - 24”

22618-17-0308Page 32Available from Empire Comfort Systems, Inc.Step 1. Install foam gasket on back side of co-axial direct vent adaptor.Step 2. Atta

Seite 27 - Colinear adaptor

22618-17-0308 Page 3345° ELBOW47.5”(1.2m)Horizontal Venting Maximum 47.5” (1.2 m) with 45° elbow.45° elbow can be purchased from a local hardware stor

Seite 28 - PVC CEMENT

22618-17-0308Page 34GAS CONNECTION INSTALLATION INSTRUCTIONSGAS CONNECTION (Line Supply)A 3/8” Flair gas line connection is supplied in the heaterGAS

Seite 29 - Colinear Transition Plate

22618-17-0308 Page 35OPERATING INSTRUCTIONS CHECKLISTBEFORE OPERATING THIS APPLIANCE, CAREFULLY PROCEED THROUGH THE FOLLOWING CHECKLIST1. Read and

Seite 30 - 45° ELBOW

22618-17-0308Page 36LIGHTING INSTRUCTIONS1. Main Electrical power supply must always be switched on to the unit with the two burner switches in the o

Seite 31 - EXTERIOR GRADE

22618-17-0308 Page 37LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EX-P

Seite 32 - MINIMUM TUBE LENGTH

22618-17-0308Page 38FAN OPERATIONThe 3-speed main convection fan will automatically start approximately 3 to 5 minutes after the heater has warmed up.

Seite 33

22618-17-0308 Page 39GAS CONVERSION INSTRUCTIONSWarning: Conversion must be done by a qualified service technician. Main burner orifices, front burner

Seite 34 - FLEXIBLE GAS

22618-17-0308Page 4SAFETY INFORMATION FOR USERS OF LP-GASPropane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state,

Seite 35 - CHECKLIST

22618-17-0308Page 40GAS CONVERSION INSTRUCTIONSWarning: Conversion must be done by a qualified service technician. Main burner orifice(s) and new gas

Seite 36 - LIGHTING INSTRUCTIONS

22618-17-0308 Page 41AUTOMATIC HUMIDIFIER OPERATIONMost gas heaters dry out the air in the room. The Mantis has in-geniously solved this problem w

Seite 37 - TO TURN OFF GAS TO APPLIANCE

22618-17-0308Page 42OPTIONAL CONTROLLERSSee your Mantis dealer for correct controller type. MODELSFRBTP Battery Operated Remote w/ Programmable Therm

Seite 38 - FAN OPERATION

22618-17-0308 Page 43OPTIONAL CONTROLLERSR: 24 Volt HotW1: Heat Relay Stage 1 (Front burner)W2: Heat Relay Stage 2 (Rear burner)C: 24 Volt Common

Seite 39 - GAS CONVERSION INSTRUCTIONS

22618-17-0308Page 44WIRING(1) (2) BLACKBLACK (3) (4) REDYELLOW (5) (6) REDBLUE (7) (8) BROWNGREY (9) (10) REDRED (11) (12) BLACKBLACK (13) (14) REDRED

Seite 40

22618-17-0308 Page 45GENERAL INFORMATIONOver Temperature Cut OutThe Mantis Power-Vent High-Efficiency Fireplace is protected against overheating

Seite 41 - 22618-17-0308 Page 41

22618-17-0308Page 46MAINTENANCEFigure 55Front door removal drawingLOG SUPPORT PLATEBURNER PLATEREAR BURNERFRONT BURNERIGNITOR ASSEMBLYFLAME SENSORFigu

Seite 42 - OPTIONAL CONTROLLERS

22618-17-0308 Page 47UNIT OPERATING FAULTSSERVICE AND INSTALLATION OF THE APPLIANCE SHOULD BE CARRIED OUT BY AUTHORIZED PER-SONNEL ONLY.THE MAJOR CAUS

Seite 43

22618-17-0308Page 48MAIN CONVECTION FANThe main convection fan in the heater should be checked, ser-viced and cleaned annually by a qualified

Seite 44 - WIRING DIAGRAM

22618-17-0308 Page 49PEDESTAL INSTALLATION INSTRUCTIONSOptional Pedestal Assembly Installation1. Remove pedestal assembly from carton. Handle p

Seite 45 - MAINTENANCE

22618-17-0308 Page 5REQUIREMENTS FOR MASSACHUSETTSFor all side wall horizontally vented gas fueled equipment installed in every dwelling, building or

Seite 46

22618-17-0308Page 50PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 22868 REAR PANEL A

Seite 47 - LOG PLACEMENT

22618-17-0308 Page 51 50 22628 GAS LINE - FRONT 51 M174 GASKET 52 11269 GAS LINE BRACKET 53 R8886 COMPRESSION FITTING 54 R8812 VALVE, N

Seite 48 - HEAT EXCHANGER

22618-17-0308Page 52PARTS VIEW1456973028335211527242819111291093429311620142926252217832133618352332

Seite 49 - 22618-17-0308 Page 49

22618-17-0308 Page 53PARTS VIEW69677284615047485354535160565548478052653940414238454689858687888178777366837690444349378270716479636257595874587568919

Seite 50 - PARTS LIST

22618-17-0308Page 54WARRANTY TERMS Purchase Date: Dealer Name/Phone:Limited Ten-Year Heat Exchanger WarrantyEmpire promises to the owner that if the

Seite 51

22618-17-0308 Page 55SERVICE NOTESParts can be ordered only through your service person or dealer. For best results, the service person or dealer shou

Seite 52 - PARTS VIEW

22618-17-0308Page 56SERVICE NOTESEMPIREEMPIREComfort SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general qu

Seite 53

22618-17-0308Page 6Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code.Recommended Gas Pipe DiameterPipe

Seite 54 - WARRANTY TERMS

22618-17-0308 Page 7Qualified Installing AgencyInstallation and replacement of gas piping, gas utilization equip-ment or accessories and repair and ser

Seite 55 - HOW TO ORDER REPAIR PARTS

22618-17-0308Page 8Model PV28SV50Input BTU/HR (KW/H) 19,000 Rear - 9,000 FrontHeight 25 1/8”Width 28 3/16”Depth 17 5/8”Gas Inlet (Pipe) 3/8” FlairEle

Seite 56 - Comfort Systems

22618-17-0308 Page 91. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide