DIRECT VENT
GAS FIREPLACE HEATER
MODEL SERIES
MILLIVOLT STANDING PILOT
DVP42DP31(N,P)-2
DIRECT IGNITION
DVP42DP51N-1
INTERMITTENT PILOT
DVP42DP71(N,P)-3
REMOTE RF
DVP42DP91(N,P)-3
UL FILE NO. MH30033
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
WARNING: If not installed, operated and maintained
in accordance with the manufacturers instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certied
kit is used.
Direct Vent Zero Clearance Gas
Fireplace Heater
GAS-FIRED
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
re department.
Installation and service must be performed by a
qualied installer, service agency or the gas sup-
plier.
WARNING: If the information in these instruc-
tions are not followed exactly, a re or explosion
may result causing property damage, personal in-
jury or loss of life.
EMPIRE
EMPIRE
Comfort Systems
Seitenansicht 0
1 2 3 4 5 6 ... 67 68

Inhaltsverzeichnis

Seite 1 - OWNER’S MANUAL

Page 1DIRECT VENT GAS FIREPLACE HEATERMODEL SERIESMILLIVOLT STANDING PILOTDVP42DP31(N,P)-2DIRECT IGNITIONDVP42DP51N-1INTERMITTENT PILOTDVP42DP71(N,P)-

Seite 2 - TABLE OF CONTENTS

31457-1-0513Page 10CLEARANCESClearance to CombustiblesBack 0" (0 mm)Side 0" (0 mm)Floor 0" (0 mm)Top Stand-off 0" (0 mm)Top Framin

Seite 3 - IMPORTANT SAFETY INFORMATION

31457-1-0513 Page 11Figure 7NOTICE: Island and Room Divider installation is possible as long as the horizontal portion of the vent system does not ex

Seite 4 - LP-GAS WARNING ODOR

31457-1-0513Page 12GAS SUPPLYThe gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas

Seite 5

31457-1-0513 Page 13INSTALLATIONFraming and Finishing 1. Choose unit location.2. Frame in replace with a header across the top. It is important to

Seite 6 - INTRODUCTION

31457-1-0513Page 14"A" 37 7/8""B" 43 3/8""C" 19 7/8"Figure 15Attention: Add 3-3/4" to “A” dimensions

Seite 7 - SPECIFICATIONS

31457-1-0513 Page 15Flush Wall InstallationFigure 16Combustible Surround InstallationFigure 17Attention: Cold climate installation recommendation: Whe

Seite 8 - VENT SYSTEMS

31457-1-0513Page 16REAR ONLY, STRAIGHT OUT THE BACK"A" "B" 6"(152mm) 5 1/8"(130mm) to 6 /2"(165mm) 9"(229mm) 8

Seite 9 - FIREPLACE DIMENSIONS

31457-1-0513 Page 17To Use the Vent Graph1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent

Seite 10 - CLEARANCES

31457-1-0513Page 18VENTING FIREPLACE - TOP (continued)Installation of Flue Heat Shield1. Remove ue insulation.2. Remove two screws on outside

Seite 11 - LOCATING FIREPLACE

31457-1-0513 Page 19VENTING FIREPLACE - TOP (continued)Below Grade InstallationWhen it is not possible to meet the required vent terminal clearances o

Seite 12 - GAS SUPPLY

31457-1-0513Page 2TABLE OF CONTENTSIMPORTANT SAFETY INFORMATION ...

Seite 13 - INSTALLATION

31457-1-0513Page 20VENTING FIREPLACE - TOP (continued)Figure 29Minimum hole location dimensions for through the wall hori-zontal installations with 90

Seite 14 - INSTALLATION (continued)

31457-1-0513 Page 21Figure 32Figure 33Figure 34EXAMPLES - TOP VENT RUN

Seite 15

31457-1-0513Page 22REAR VENT CONVERSIONConverting ue take-off to rear ventingWhen switching out the ue and inlet vent collars to run horizontally of

Seite 16

31457-1-0513 Page 23 Acceptable vertical and horizontal vent run. Unacceptable vertical and horizontal vent run.Figure 35Venting Graph (Dimensions i

Seite 17 - VENTING FIREPLACE - TOP

31457-1-0513Page 24Figure 36Figure 37Figure 38Figure 39Model Maximum Pipe Length H1DVP42 24"Model Maximum Pipe Length H1DVP42 24"EXAMPLES -

Seite 18

31457-1-0513 Page 25Figure 40A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum]B = clearance to window or do

Seite 19

31457-1-0513Page 268" VENTING FRAMING AND FINISHINGInstalling Support BracketsA horizontal pipe support MUST BE used for each 3 feet of horizonta

Seite 20

31457-1-0513 Page 278" VENTING FRAMING AND FINISHING (continued)Figure 43Figure 44Figure 45See Horizontal Termination Page 29 and Vertical Termin

Seite 21 - EXAMPLES - TOP VENT RUN

31457-1-0513Page 28Termination clearance for buildings with combustible and noncombustible exteriors.Vertical Sidewall InstallationsImportant! Minimum

Seite 22 - REAR VENT CONVERSION

31457-1-0513 Page 29HORIZONTAL TERMINATIONNOTICE: Termination cap should pass through the wall restop from the exterior of the building. Adjus

Seite 23

31457-1-0513 Page 3DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLEDBefore enclosing the vent pipe assembly, operate the appliance to

Seite 24 - EXAMPLES - REAR VENT RUN

31457-1-0513Page 30VERTICAL TERMINATIONLocate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this

Seite 25 - VENT CLEARANCES

31457-1-0513 Page 31VERTICAL TERMINATION (continued)Figure 50 CAUTIONTreatment of restop spacers and construction of the chase may vary with the type

Seite 26

31457-1-0513Page 32DVVK-5F FLEX VENT INSTRUCTIONSThe DVVK-5F FLEX VENT KIT includes the following compo-nents:• Horizontal Termination Cap• 4-foot

Seite 27

31457-1-0513 Page 33PROPANE/LP GAS CONVERSIONAModel AIR SHUTTER SETTINGSBURNER ORIFICEOpening "A" Propane/LP OriceDVP42 FULL OPEN #52Figure

Seite 28 - TERMINATION CLEARANCES

31457-1-0513Page 34LOG PLACEMENT (4 LOG SET)Before you begin: This replace is supplied with a set of four ceramic ber logs. Do not handle

Seite 29 - HORIZONTAL TERMINATION

31457-1-0513 Page 35The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the

Seite 30 - VERTICAL TERMINATION

31457-1-0513Page 36STANDING PILOT OPERATING INSTRUCTIONS Remote/Off/On SwitchThe replace is equipped with a Remote/OFF/ON switch. A wire harness is a

Seite 31 - CAUTION

31457-1-0513 Page 37Figure 63MILLIVOLT STANDING PILOT WIRING DIAGRAM

Seite 32

31457-1-0513Page 381. Stop! Read the safety information above.2. Set REMOTE/OFF/ON switch to OFF.3. Turn off all electric power to the appliance (i

Seite 33 - PROPANE/LP GAS CONVERSION

31457-1-0513 Page 39With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do

Seite 34 - LOG PLACEMENT (4 LOG SET)

31457-1-0513Page 4Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must nd out if you can smell

Seite 35

31457-1-0513Page 40A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the oor because some gas is heavier than

Seite 36

31457-1-0513 Page 41DIRECT IGNITION WIRING DIAGRAMLED CODESSteady ON Normal operation, power ON to control2 Flashes 3 unsuccessful ignition trials3 Fl

Seite 37 - Figure 63

31457-1-0513Page 421. Remove glass door and place away from the replace.2. Turn on gas shut off valve. Follow ignition procedure.3. If burner does

Seite 38 - TO TURN OFF GAS TO FIREPLACE

31457-1-0513 Page 43The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in a

Seite 39

31457-1-0513Page 44IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS5.25 VDC ELECTRONIC CONTROL VALVEThe electronic control valve system includes the abili

Seite 40 - TO TURN OFF GAS TO APPLIANCE

31457-1-0513 Page 45IPI ELECTRONIC SYSTEM WIRING DIAGRAMWARNING: Improper installation, adjustment, alteration, service or maintenance can cause prope

Seite 41 - OPTIONAL REMOTE CONTROL

31457-1-0513Page 46TO TURN OFF GAS TO FIREPLACEGAS COCK1. STOP! Read the safety information above.2. Turn OFF electric power to the appliance.3. Re

Seite 42 - PURGE PROCEDURE

31457-1-0513 Page 47Brief Description of the ComponentsThe gas valve is tted with a manual HI/LO knob to allow for man-ual modulation of the gas outl

Seite 43

31457-1-0513Page 481If the DFC giving signal lock out:The board should be unlocked toreinitiate a pilot flame ignition (forthe correct unlock sequence

Seite 44

31457-1-0513 Page 49INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING2Main burner lightswhen the pilot onlyshould light.Pilot holds the flame?.Main bu

Seite 45

31457-1-0513 Page 5REQUIREMENTS FOR MASSACHUSETTSFor all side wall horizontally vented gas fueled equipment installed in every dwelling, building or s

Seite 46

31457-1-0513Page 50RF OPERATING INSTRUCTIONSRF VALVE OPERATION (AF-4040 Electronic Gas Valve system only)Please refer to the separate instructions for

Seite 47

31457-1-0513 Page 51RF MAINTENANCE INSTRUCTIONSMAINTENANCEMaintenance frequency must be determined individually for each application. Some considerati

Seite 48 - 31457-1-0513Page 48

31457-1-0513Page 52Figure 67RF WIRING DIAGRAMNOTICE: For "RF" Fireplace models with Premium Multi-Function Remote Control, Refer to the sepa

Seite 49 - 31457-1-0513 Page 49

31457-1-0513 Page 53FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSI

Seite 50 - RF OPERATING INSTRUCTIONS

31457-1-0513Page 54Please NoteIt is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up

Seite 51 - RF MAINTENANCE INSTRUCTIONS

31457-1-0513 Page 55MAINTENANCE AND SERVICEReassembly and Resealing Gas Accumulation Relief SystemGlass Frame Assembly and Combustion ChamberWhenever

Seite 52 - RF WIRING DIAGRAM

31457-1-0513Page 56PARTS LISTIndex No.Part NumberDescriptionDVP42DP3 DVP42DP5 DVP42DP7 DVP42DP91 R7654 R7654 R7654 R7654 Insulation, Flue2 17426 17426

Seite 53

31457-1-0513 Page 57PARTS LIST (continued)41 R3436 - - - Remote/On/Off Switch42 - - R2522 - On/Off Switch43 - R7615 - - Cord Set44 - R8144 - - Wire Ha

Seite 54 - MAINTENANCE AND SERVICE

31457-1-0513Page 58PARTS VIEW

Seite 55

31457-1-0513 Page 59To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provid

Seite 56 - PARTS LIST

31457-1-0513Page 6Instructions to Installer1. Installer must leave instruction manual with owner after installation.2. Installer must have ow

Seite 57 - PARTS LIST (continued)

31457-1-0513Page 60Attention: Install blower assembly before connecting gas inlet supply lineNOTICE: Junction box on right side of replace m

Seite 58 - PARTS VIEW

31457-1-0513 Page 611 R7731 BLOWER MOTOR2 31920 SWITCH ASSEMBLY3 R4192 SPEED CONTROL KNOB4 R4186 SPEED CONTROLFBB4 VARIABLE SPEED BLOWER INSTALLATION

Seite 59 - HOW TO ORDER REPAIR PARTS

31457-1-0513Page 62CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LO-CAL, CITY AND STATE BUILDING C

Seite 60

31457-1-0513 Page 63The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond w

Seite 61 - 4 R4186 SPEED CONTROL

31457-1-0513Page 64Web Site www.empirecomfort.comEmpire Comfort Systems918 Freeburg AvenueBelleville, Illinois 62220-2623CLEARANCES TO COMBUSTIBLESGA

Seite 62

31457-1-0513 Page 65Web Site www.empirecomfort.comEmpire Comfort Systems918 Freeburg AvenueBelleville, Illinois 62220-2623GAS-FIREDFRAMING DIMENSIONF

Seite 63 - ACCESSORIES

31457-1-0513Page 66WARRANTYEmpire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the peri

Seite 64 - Comfort Systems

31457-1-0513 Page 67APPLIANCE SERVICE HISTORYDate Dealer Name Service Technician Name Service Performed/Notes

Seite 65

31457-1-0513Page 68EMPIREEMPIREComfort SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general question about o

Seite 66 - WARRANTY

31457-1-0513 Page 7DVP42Input Btu/hr Maximum28,000(NAT)28,000 (LP) Btu/hr Minimum (millivolt only)19,000 (NAT)22,000 (LP)KWH (Maximum) 8.2

Seite 67 - APPLIANCE SERVICE HISTORY

31457-1-0513Page 8Begin the vent system installation by selecting the type of venting to be installed and the path that it will take. Verify that clea

Seite 68

31457-1-0513 Page 9FIREPLACE DIMENSIONSA 34 3/4" (882.7 mm)B 43" (1092.2 mm)C 19 7/8" (505 mm)D 25" (635 mm)E 40" (1016 mm)G