DIRECT VENT GAS FIREPLACE HEATERMODEL SERIESMILLIVOLT STANDING PILOTDVP42FP3(0,1,2,3)(N,P)-2DVP48FP3(0,1,2,3)(N,P)-2INTERMITTENT PILOTDVP42FP7(0,1,2,3
21759-6-0608Page 10REAR VENT CONVERSIONConverting flue take-off to rear ventingWhen switching out the flue and inlet vent collars to run horizontally of
21759-6-0608 Page 11Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow fo
21759-6-0608Page 12DVP42 DVP48"A" 37 3/4" 37 3/4""B" 43 3/8" 49 3/8""C" 19 7/8" 19 7/8"Fig
21759-6-0608 Page 13Flush Wall InstallationFigure 12Combustible Surround InstallationFigure 13Vent Runs (Figures 14, 15, 16, 17 and 18)In planning the
21759-6-0608Page 14HORIZONTAL ONLY, STRAIGHT OUT THE BACKFigure 15VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALLCORNER INSTALLATION VERTICAL, 90° ELBO
21759-6-0608 Page 15To Use the Vent Graph (Figure 19)1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the S
21759-6-0608Page 16Figure 21Examples of possible venting systems using two (2) 90° elbows. V is listed as minimum vertical dimensions and H1 + H2 is
21759-6-0608 Page 17MAXIMUM HORIZONTALRUN WITH NO VERTICALRISE AND 90° ELBOWMAXIMUM HORIZONTALRUN WITH MINIMUMVERTICAL RISE AND90° ELBOWminimumFigure
21759-6-0608Page 18Figure 26Figure 27Figure 2824”24” MINIMUMCLEARANCE TOCOMBUSTIBLESEXAMPLES - TOP VENT RUN
21759-6-0608 Page 19VENTING EXAMPLES WHEN USING DVA47 ADAPTORVertically Off Top of Fireplace OnlyFigure 29Figure 30Figure 31
21759-6-0608Page 2Important Safety Information ...
21759-6-0608Page 20Installation InstructionsThis termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use wit
21759-6-0608 Page 21PRE-INSTALLATION INFORMATION:Items Required For Installation:Tools Building SuppliesPhillips ScrewdriverHammerSaw and/or saber saw
21759-6-0608Page 221. Unpack vent components and check all items for shipping damage.2. For this venting system to operate as designed
21759-6-0608 Page 2310. With the flex vent assembly and the 48” long hard pipe components laid out on the floor, begin securing these parts t
21759-6-0608Page 2417. To attach the vent connections at the fireplace, be sure the 7” diameter adapter collar has been installed per step 3. Apply a
21759-6-0608 Page 25Figure 38StormClearance toCombustiblesCollarExteriorRoofRoofFlashingRoof JackAdjustableAssembly4' Long Rigid PipeDirect VentF
21759-6-0608Page 26Vertical Flex Termination KitItem Number Item Description Repair Part No.Quantity Supplied1 4”/7” Vertical Termination Cap MF100038
21759-6-0608 Page 27Figure 39 Acceptable vertical and horizontal vent run. Unacceptable vertical and horizontal vent run.Venting Graph (Dimensions i
21759-6-0608Page 28Figure 40Figure 41Figure 42Figure 43Model Maximum Pipe Length H1DVP42 24"DVP48 18"Model Maximum Pipe Length H1DVP42 24&qu
21759-6-0608 Page 29CAUTION: Sharp edges, use protective gloves when installing.Tools Needed for Installation:Sheet metal snips5/16” nut driver
21759-6-0608 Page 3DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLEDBefore enclosing the vent pipe assembly, operate the appliance to
21759-6-0608Page 307. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168mm) diameter tube f
21759-6-0608 Page 31Follow correct option according to venting method.Connecting Directly to FireplaceIf the air inlet and flue outlet tubes are to be
21759-6-0608Page 32INSTALLATION1. Unpack vent components and check that all items are included.2. Check to see that the vent spacer springs are lo
21759-6-0608 Page 33Termination clearance for buildings with combustible and noncombustible exteriors.Vertical Sidewall InstallationsImportant! Minimu
21759-6-0608Page 34Figure 55A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum]B = clearance to window or door
21759-6-0608 Page 35Installing Vent Components (Figure 56)Begin the vent system installation by installing the first Simpson Duravent component, 90° el
21759-6-0608Page 36Installing Vent Components (Figure 57)Begin the vent system installation by installing the first Simpson Duravent component, 90° elb
21759-6-0608 Page 37Installing Support Brackets (Figure 58)A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports
21759-6-0608Page 38Figure 60Figure 62See Horizontal Termination Page 41 and Vertical Termination Pages 43 and 44.Figure 618" VENTING FRAMING AND
21759-6-0608 Page 39Installing Support Brackets (Figure 63)A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pi
21759-6-0608Page 4Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell
21759-6-0608Page 40Figure 67See Horizontal Termination Page 41 and Vertical Termination on Pages 43 and 44.6 ⅝" VENTING FRAMING AND FINISHING (co
21759-6-0608 Page 41NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap t
21759-6-0608Page 42INSTALLATION1. Unpack vent components and check that all items are included.2. Check to see that the vent spacer springs are lo
21759-6-0608 Page 43Locate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this nail through this c
21759-6-0608Page 44Reassembly and Resealing Gas Accumulation Relief SystemGlass Frame Assembly and Combustion ChamberWhenever the glass frame assembly
21759-6-0608 Page 45WARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this
21759-6-0608Page 46The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the g
21759-6-0608 Page 47STANDING PILOT OPERATING INSTRUCTIONS Remote/Off/On SwitchThe fireplace is equipped with a Remote/OFF/ON switch. A wire harness is
21759-6-0608Page 48Figure 82(OPTIONAL) THERMOSTAT(OPTIONAL) WALL SWITCHSTANDING PILOT WIRING DIAGRAM
21759-6-0608 Page 491. Stop! Read the safety information above.2. Set REMOTE/OFF/ON switch to OFF.3. Turn off all electric power to the appliance (
21759-6-0608 Page 5REQUIREMENTS FOR MASSACHUSETTSFor all side wall horizontally vented gas fueled equipment installed in every dwelling, building or s
21759-6-0608Page 50With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do
21759-6-0608 Page 511. To wire Junction Box Receptacle, remove the tab on the side of the receptacle (hot side) to split receptacle. This will be req
21759-6-0608Page 521. Stop! Read the safety information above.2. Set the thermostat to lowest setting.3. Turn off all electric power to the applian
21759-6-0608 Page 53GENERAL: All fireplaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fan oper
21759-6-0608Page 54spark generator and energizes the second main valve operator. The second main valve opens and gas flows to the main burner, where i
21759-6-0608 Page 55Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ign
21759-6-0608Page 56INTERMITTENT PILOT TROUBLESHOOTING (continued)
21759-6-0608 Page 57INTERMITTENT PILOT TROUBLESHOOTING (continued)Green LED Status CodesGreen LED Flash Code (X + Y)aIndicates Next System Action Reco
21759-6-0608Page 58Functions• Flame powered system• Flame powered flame modulation• Electronics integrated into valve to provide thermostat, flame, a
21759-6-0608 Page 59FIRST USE OF TRANSMITTERStatus ActionBegin communication between transmitter and receiver/valve. Move LOCAL/REMOTE Switch to LOCAL
21759-6-0608Page 6Instructions to Installer1. Installer must leave instruction manual with owner after installation.2. Installer must have ow
21759-6-0608Page 60WIRING DIAGRAM WITH BLOWERFigure 85RF WIRING DIAGRAM
21759-6-0608 Page 611. STOP! Read the safety information above.2. Turn off all electric power to the appliance (if applicable).3. Lower lou
21759-6-0608Page 62Please NoteIt is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up
21759-6-0608 Page 6315*1212789101112201913122322a21171816123456111427282931302433323440384239a36a37a415239b34333224302928273136b444637b33343236c37c312
21759-6-0608Page 64INDEX NO. PART NUMBER DESCRIPTIONDVP42 DVP481R-7654 R-7654 FLUE INSULATION2 17426 17426 FLUE INSULATION RETAINER3R-7567 R-7567 INLE
21759-6-0608 Page 65INDEX NO. PART NUMBER DESCRIPTIONDVP42 DVP4826P200 P200 ORIFICE FITTING27P203 P213 ORIFICE (NAT)27P185 P250 ORIFICE (LP)28R-5676 R
21759-6-0608Page 66Attention: Install blower assembly before connecting gas inlet supply lineNote: Junction box on right side of fireplace must be p
21759-6-0608 Page 67110 VOLT ACJUNCTION BOXWHITESPEEDCONTROLFANSWITCHGROUNDBLACKFAN1 FBB4 B L O W E R A S S E M B LY COMPLETE2 R7649 FAN CONTROL3 R4
21759-6-0608Page 68CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE B
21759-6-0608 Page 69The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond w
21759-6-0608 Page 7Figure 1DVP42 DVP48A 43"1092mm49"1245mmB 40"1016mm46"1168mmC 25 1/16"636 mm25 1/16"636 mmD 37 5/8&quo
21759-6-0608Page 70Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts
21759-6-0608 Page 71SERVICE NOTES
21759-6-0608Page 72Empire Comfort Systems, Inc.918 Freeburg Ave. Belleville, IL 62220PH: 618-233-7420 or 800-851-3153FAX: 618-233-7097 or 800-443-864
21759-6-0608Page 8Mantel Chart (Figure 3)Figure 3Clearances (Figure 4)Clearance from top front edge of fireplace to ceiling is 36"Clearance from s
21759-6-0608 Page 9Figure 6 The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas